Parameter List 0
You can activate the special extra functions of the controller using the parameters of this parameter list.
Function | Parameter | Description | Parameter | Note | Factory |
|---|---|---|---|---|---|
Accept the current | w-setup | Automatic acceptance | 0 | Acceptance | 0 |
1 | Acceptance |
| |||
w-setup | Manual acceptance in | 0 | Acceptance | 0 | |
1 | Acceptance |
| |||
w-setup | Automatic acceptance | 0 | Acceptance | 0 | |
1 | Acceptance |
| |||
w-setup | Automatic acceptance when changing the guiding mode | 0 | Acceptance | 0 | |
1 | Acceptance |
| |||
Speed-dependent | vel. gain | Activate the speed- | 0 | Guiding | 0 |
1 | Guiding |
| |||
vel. gain | Source for the speed signal | 0 | Analogue input | Analogue | |
1 | reserved |
| |||
Vel. Start % | Starting value of the control limitation | 0 … |
| 20 % | |
Vel. mV | Speed signal at maximum machine speed | 0 |
| 10,000 mV | |
OK relay | OK-relay | Reverse the polarity of | 0 | Reverse polarity | 0 |
1 | Reverse polarity |
| |||
Line monitoring | cls ref width | Automatic acceptance of the line width when activating the automatic operating mode | 0 |
| 0 |
1 |
|
| |||
Adjustment of the guiding setpoint via remote control inputs | setpoints | In automatic operating mode: | 0 | Adjustment of the guiding setpoint deactivated | 0 |
1 | Adjustment of the guiding setpoint activated |
| |||
Offset value for the guiding setpoint (only with CCD camera) | setp-offs. | Activate offset value | 0 | Offset value | 0 |
1 | Offset value |
| |||
setpoint offs. | Enter offset value | depending on the sensor |
| 0 | |
Tear-off detection with CCD camera | tear off | Activate tear-off detection | 0 | Tear-off detection deactivated | 0 |
1 | Tear-off detection activated |
| |||
tear off | Min. change of the sensor value per scanning cycle so that a tear-off is detected | depending on the sensor |
| 0 pixel | |
tear off | Scanning cycle | ≥ 5 ms |
| 5 ms | |
tear off lock | Blocking time |
|
| 0 ms | |
tear off | Blocking hold time |
|
| 0 ms | |
CANopen | userprotocol xxxx | Selecting the communication protocol |
| Standard protocol = 3100 | 0 |
Offset value for sensor positioner | setp-offs. fvg act. | Activate offset value | 0 | Offset value | 0 |
1 | Offset value |
| |||
setpoint offs. fvg | Enter offset value | depending on the type of sensor positioner |
| 0 |