Function
With tear-off detection activated, in automatic mode the sensor value of the CCD camera is read-in at a pre-set time interval (scanning cycle). If a tear on the web edge occurs in the measuring range of the CCD camera, the sensor value read in jumps suddenly. If the change of the sensor value exceeds from one scanning cycle to the next by a determined minimum value, the change is detected as tear-off and the web guiding system is blocked automatically for the pre-selected blocking time. It is possible to deactivate the tear-off detection after the detection of a tear-off for a pre-selected period (blocking hold time).
With the following parameters of the public parameter list (parameter list 0), you can activate the tear-off detection and adapt the function to your individual application.
Function | Parameter | Parameter value | Description |
|---|---|---|---|
Activate tear-off detection | tear off active | 0 (OFF) | Function deactivated |
1 (ON) | Function activated | ||
Min. change of the sensor value per scanning cycle so that a tear-off is detected | tear off value digits | depending on the sensor | Factory setting: 0 pixel |
Scanning cycle | tear off probe time ms | ≥ 5 ms | Factory setting: 5 ms |
Blocking time | tear off lock ms |
| Factory settings: 0 ms |
Blocking hold time | tear off inhibit ms |
| Factory settings: 0 ms |
To select the public parameter list (parameter list 0) see Extended Device Settings.