Parameter List 2
You make the basic settings for the width measurement and the oscillation using the parameters of this parameter list.
Function | Parameter | Description | Parameter value | Note | Factory setting |
|---|---|---|---|---|---|
Special operating mode | edge pos.tol.warning µm | Reserved for special applications | |||
edge pos.tol.error µm | |||||
line width ref. µm | |||||
line width tol.warn µm | |||||
line width tol.error µm | |||||
Oscillation | osc-mode 0=tri 1=sin | Oscillation form | 0 | Triangular curve | 0 |
1 | Sinus curve |
| |||
Speed-dependent oscillation | osc speed dep active | Activate the speed-dependent oscillation | 0 | Oscillation deactivated | 0 |
1 | Oscillation activated |
| |||
osc speed % low lock | Starting threshold of the speed signal | 0 … 99 % |
| 2 % | |
osc mV at 100% speed | Speed signal at maximum machine speed | 0 … 10,000 mV |
| 10,000 mV | |
osc sp. source 0=analog | Source for the speed signal | 0 | Analogue input 0 … 10 V= (terminal 56/57) | Analogue input 0 … 10 V= | |
1 | reserved |
| |||
osc-factor 0 or 1 | Range of values for the oscillation frequency | 0 | 0.1 … 50.0 [1/min] | 0 | |
1 | 1 … 500 [1/min] |
| |||
Web/line width measurement | ref width w.low active | Activate lower warning limit | 0 | Lower warning limit deactivated | 0 |
1 | Lower warning limit activated |
| |||
ref width w.up active | Activate upper warning limit | 0 | Upper warning limit deactivated | 0 | |
1 | Upper warning limit activated |
| |||
ref width e.low active | Activate lower error limit | 0 | Lower error limit deactivated | 0 | |
1 | Lower error limit activated |
| |||
ref width e.up active | Activate upper error limit | 0 | Upper error limit deactivated | 0 | |
1 | Upper error limit activated |
| |||
ref width µm | Target width | — |
| 1,000 µm | |
ref width warn low µm | Lower Warning limit | — |
| 1,000 µm | |
ref width warn up µm | Upper warning limit | — |
| 1,000 µm | |
ref width err low µm | Lower error limit | — |
| 1,000 µm | |
ref width err upp µm | Upper error limit | — |
| 1,000 µm | |
Controller interlock | lock pos. contr. active | Automatic activation of the position control with controller interlock | 0 | Activation of the position control deactivated | 0 |
1 | Activation of the position control activated |
| |||
Setpoint for sensor 3 | sensor3 setp. zero | The value 0 is always used as setpoint | 0 | Setpoint 0 deactivated | 0 |
1 | Setpoint 0 activated |
| |||