Parameter List 2

You make the basic settings for the width measurement and the oscillation using the parameters of this parameter list.

Rotate the smartphone by 90 degrees to show the entire table.

Function

Parameter

Description

Parameter value

Note

Factory setting

Special operating mode

edge pos.tol.warning µm

Reserved for special applications

edge pos.tol.error µm

line width ref. µm

line width tol.warn µm

line width tol.error µm

Oscillation

osc-mode 0=tri 1=sin

Oscillation form

0

Triangular curve

0

1

Sinus curve

 

Speed-dependent oscillation

osc speed dep active

Activate the speed-dependent oscillation

0
(OFF)

Oscillation deactivated

0
(OFF)

1
(ON)

Oscillation activated

 

osc speed % low lock

Starting threshold of the speed signal

0 … 99 %

 

2 %

osc mV at 100% speed

Speed signal at maximum machine speed

0 … 10,000 mV

 

10,000 mV

osc sp. source 0=analog

Source for the speed signal

0

Analogue input 0 … 10 V= (terminal 56/57)

Analogue input 0 … 10 V=

1

reserved

 

osc-factor 0 or 1

Range of values for the oscillation frequency

0

0.1 … 50.0 [1/min]

0

1

1 … 500 [1/min]

 

Web/line width measurement

ref width w.low active

Activate lower warning limit

0
(OFF)

Lower warning limit deactivated

0
(OFF)

1
(ON)

Lower warning limit activated

 

ref width w.up active

Activate upper warning limit

0
(OFF)

Upper warning limit deactivated

0
(OFF)

1
(ON)

Upper warning limit activated

 

ref width e.low active

Activate lower error limit

0
(OFF)

Lower error limit deactivated

0
(OFF)

1
(ON)

Lower error limit activated

 

ref width e.up active

Activate upper error limit

0
(OFF)

Upper error limit deactivated

0
(OFF)

1
(ON)

Upper error limit activated

 

ref width µm

Target width

 

1,000 µm

ref width warn low µm

Lower Warning limit

 

1,000 µm

ref width warn up µm

Upper warning limit

 

1,000 µm

ref width err low µm

Lower error limit

 

1,000 µm

ref width err upp µm

Upper error limit

 

1,000 µm

Controller interlock

lock pos. contr. active

Automatic activation of the position control with controller interlock

0
(OFF)

Activation of the position control deactivated

0
(OFF)

1
(ON)

Activation of the position control activated

 

Setpoint for sensor 3

sensor3 setp. zero

The value 0 is always used as setpoint

0
(OFF)

Setpoint 0 deactivated

0
(OFF)

1
(ON)

Setpoint 0 activated