Parameter List 0

You can activate the special extra functions of the controller using the parameters of this parameter list.

Rotate the smartphone by 90 degrees to show the entire table.

Function

Parameter

Description

Parameter
value

Note

Factory
setting

Accept the current
edge position as the
guiding setpoint

w-setup
man->auto

Automatic acceptance
when activating the
automatic operating mode

0
(OFF)

Acceptance
deactivated

0
(OFF)

1
(ON)

Acceptance
activated

 

w-setup
by command

Manual acceptance in
manual operating mode

0
(OFF)

Acceptance
deactivated

0
(OFF)

1
(ON)

Acceptance
activated

 

w-setup
by input

Automatic acceptance
with digital input signal

0
(OFF)

Acceptance
deactivated

0
(OFF)

1
(ON)

Acceptance
activated

 

w-setup
by edge change

Automatic acceptance when changing the guiding mode

0
(OFF)

Acceptance
deactivated

0
(OFF)

1
(ON)

Acceptance
activated

 

Speed-dependent
guiding

vel. gain

Activate the speed-
dependent guiding

0
(OFF)

Guiding
deactivated

0
(OFF)

1
(ON)

Guiding
activated

 

vel. gain
by var

Source for the speed signal

0

Analogue input
0 … 10 V⎓
(terminal 56/57)

Analogue
input
0 … 10 V⎓

1

reserved

 

Vel. Start %
0..99

Starting value of the control limitation

0


99 %

 

20 %

Vel. mV
max speed

Speed signal at maximum machine speed

0

10,000 mV

 

10,000 mV

OK relay

OK-relay
invert

Reverse the polarity of
the OK relay

0
(OFF)

Reverse polarity
deactivated

0
(OFF)

1
(ON)

Reverse polarity
activated

 

Line monitoring
(with sensor
CLS Pro 600)

cls ref width
by var

Automatic acceptance of the line width when activating the automatic operating mode

0
(OFF)

 

0
(OFF)

1
(ON)

 

 

Adjustment of the guiding setpoint via remote control inputs

setpoints
by Io active

In automatic operating mode:
Adjustment of the guiding setpoint via the remote control inputs for the arrow keys

0
(OFF)

Adjustment of the guiding setpoint deactivated

0
(OFF)

1
(ON)

Adjustment of the guiding setpoint activated

 

Offset value for the guiding setpoint (only with CCD camera)

setp-offs.
cam M12 act.

Activate offset value

0
(OFF)

Offset value
deactivated

0
(OFF)

1
(ON)

Offset value
activated

 

setpoint offs.
cam M12

Enter offset value

depending on the sensor

 

0

Tear-off detection with CCD camera

tear off
active

Activate tear-off detection

0
(OFF)

Tear-off detection deactivated

0
(OFF)

1
(ON)

Tear-off detection activated

 

tear off
value digits

Min. change of the sensor value per scanning cycle so that a tear-off is detected

depending on the sensor

 

0 pixel

tear off
probe time
ms

Scanning cycle
(time interval for reading in the sensor values)

≥ 5 ms

 

5 ms

tear off lock
ms

Blocking time
(blocking period)

 

 

0 ms

tear off
inhibit ms

Blocking hold time
(time from detecting the end of a tear until a new tear can be detected)

 

 

0 ms

CANopen
user gateway

userprotocol xxxx

Selecting the communication protocol

 

Standard protocol = 3100

0

Offset value for sensor positioner

setp-offs. fvg act.

Activate offset value

0
(OFF)

Offset value
deactivated

0
(OFF)

1
(ON)

Offset value
activated

 

setpoint offs. fvg

Enter offset value

depending on the type of sensor positioner

 

0