Guiding Modes
The controller permits the following web guiding modes:
- Web edge guiding
(guiding to the right or the left web edge) - Web center-line guiding
- Guiding on continuous or interrupted printed lines (in conjunction with the CLS Pro 600 line and contrast sensor)
- Guiding on continuous or interrupted contrast edges (in conjunction with the CLS Pro 600 line and contrast sensor)
- Watchdog
Guiding to a printed line or contrast edge with automatic switching to web edge guiding when the printed line / contrast edge is interrupted or lost