Before switching on
Before switching on the Watchdog function for the first time, the following preparation measures must be carried out:
- ▶Carry out separate commissioning for the guiding with the CLS Pro 600 line and contrast sensor and the guiding with the edge sensor (capture sensor).
- ▶Carry out the material setup for the edge sensor.
- ▶Carry out the setup for the CLS Pro 600 line and contrast sensor (see separate operating instructions Line and contrast sensorCLS Pro 600, EDP no. MD.323).
- ▶Optimize the controller gain for both sensors.

When the Watchdog function is active, changes to the controller gain are only effective on the CLS Pro 600 line and contrast sensor.
- ▶Set the guiding setpoint of the CLS Pro 600 line and contrast sensor to the value 0 (see Switching on the Watchdog, Step 4).

If the optional electronic remote precision adjustment EFE 1 is connected to the controller then the guiding setpoint must be set to the value 0 using the potentiometer of the EFE 1 (see Electronic Remote Precision Adjustment (Option)).