X100 ... 104 - Connection of CAN Bus Participants

The CAN bus participants (ekr commander control panel, digital edge sensors, additional ekr commander control panel, ...) are connected to the controller using a 4-pin micro-style plug M8.

Contact assignment in the plug connector
Rotate the smartphone by 90 degrees to show the entire table.

Contact

Signal

Wire colour

Comments

1

+24 V⎓ output

brown

Leads internally to terminal strip X8 or X9

2

CAN-H

white

3

CAN-GND

green

4

CAN-L

yellow