Terminal Strip X10 - Controller Interlock, OMG 4, OMG 8, CK 37, EFE 1

Rotate the smartphone by 90 degrees to show the entire table.

X10

Terminal

Function

Wire Colour

Note

OMG 4

OMG 8, CK 37

EFE 1

1

+24 V⎓

 

 

 

Output +24 V⎓ for controller interlock

2

Controller interlock
(blocking)

 

 

 

Applies for all operating modes
(Automatic, Manual mode, Center positioning).
Bridge with terminal 1 if not used.

3

GND

 

 

 

Ground for controller interlock

4

+12 V⎓

pink

brown / black

 

Power supply +12 V⎓
for OMG 4 (see also Terminal Strip X7 - Actuator, OMG 4), OMG 8, CK 37 (Namur A)

5

Namur

 

blue

 

Input OMG 8, CK 37 (Namur B)

6

+12 V⎓

 

 

pink

Power supply +12 V⎓ for EFE 1

7

EFE

 

 

grey

Input EFE 1

1) Standard: 0 … +12 V⎓, centre = +6 V⎓

2) Optional: 0 … +10 V⎓, centre = +5 V⎓

Prerequisite for 2):

  • No OMG 8 is connected.
  • Jumper between terminal 4 and 5 is attached.

8

GND

 

 

yellow

Ground for EFE 1