With the electronic remote precision adjustment EFE 1, you set the guiding setpoint of the web in the automatic operating mode.
If the optional electronic remote precision adjustment EFE 1 is connected to the controller, adjust the guiding setpoint using only the potentiometer of the EFE 1. The function of the arrow keys on the control panel of the controller is then blocked in automatic mode.
Setting the guiding setpoint
Press the Automatic key.
The LED of the key illuminates.
The controller switches to automatic mode.
Turn the Potentiometer of EFE 1 until the desired guiding setpoint is reached.
The current guiding setpoint is shown in the operating display in the display of the control panel (see Overview). The value is briefly displayed inverse after changing each time.