Automatic Material Setup
This chapter describes the normal procedure for saving the bright / dark values.

You have to perform the material setup for each edge sensor (sensor 1, sensor 2) separately.
- Remove any material that may be present from the connected edge sensors and clean the sensor scanning areas.
- Select the desired sensor by pressing the respective key Sensor 1 or Sensor 2.
- The LED of the key will illuminate.

- Activate the automatic material setup (see Activating the Material Setup).

- The adjacent screen appears in the display (here with Sensor 1 selected). The animation shows the operating steps necessary for generating the bright / dark values:
- The hand moves the material into the sensor scanning area (dark value) and back out again (bright value).

- Completely clear the selected sensor's scanning area (no material in the scanning area).
- The bright value measured is displayed.

- Completely cover the selected sensor's scanning area with the material to be scanned for at least 2 seconds.
- The dark value measured is displayed.

- Press the
button.
- The material setup for the selected sensor is completed.
- The bright / dark values determined are saved.
- The setup menu is displayed.