Truth Tables
Digital inputs | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Function | Terminal strip | X14 | X15 | ||||||||||
Terminal | 10 | 11 | 12 | 13 | 14 | 15 | 18 | 19 | 20 | 21 | 22 | 23 | |
LED | H1 | H2 | H3 | H4 | H5 | H6 | H7 | H8 | H9 | H10 | H11 | H12 | |
Automatic |
|
|
| X | X | X | X | X | X | X | X | — | |
Manual operation |
|
|
| X | X | X | X | X | X | X | X | — | |
Centre position |
|
|
| X | X | X | X | X | X | X | X | — | |
Web edge guiding | X | X | X |
|
| X | X | X | X | X | X | — | |
Web edge guiding | X | X | X |
|
| X | X | X | X | X | X | — | |
Web center-line guiding | X | X | X |
|
| X | X | X | X | X | X | — | |
Left arrow key | X | X | X | X | X |
|
| X | X | X | X | — | |
Right arrow key | X | X | X | X | X |
|
| X | X | X | X | — | |
Line / contrast / feature guiding Sensor 3 | X | X | X | X | X | X | X |
| X | X | X | — | |
Keyboard interlock** | X | X | X | X | X | X | X | X |
| X | X | — | |
Controller interlock** | X | X | X | X | X | X | X | X | X |
| X | — | |
Setup lock** | X | X | X | X | X | X | X | X | X | X |
| — | |
* Restriction does not apply to controllers with firmware versions ≥ 3.2.13 | |
** 1 = Function active, 0 = Function inactive |
|
1 = high (+24 V⎓) | tlow, thigh: min. 100 ms |
0 = low (0 V⎓ (GND) or terminal open) |
|
X = not relevant |
|
— = reserved |
|
Digital outputs | |||||
|---|---|---|---|---|---|
Function | Terminal strip | X16 | |||
Terminal | 26 | 27 | 28 | 29 | |
LED | H13 | H14 | H15 | H16 | |
Position of the guiding device corrected in operating mode automatic |
| X | X | X | |
Software limit switch active / motor overcurrent / guiding device in end position | X |
| X | X | |
Brake function (actuator EMS 23B) | X | X |
| X | |
Not used | X | X | X |
| |
1 = high (+24 V⎓) | thigh: min. 100 ms |
X = not relevant |
|
You can deactivate the remote control function using the DIL switch S5.5 in order to simplify commissioning (see Setting DIL Switch S5).