Setting DIL Switch S5

Using DIL switch S5, carry out the following settings:
- Reverse the actuator motor rotation direction
- Adjust the assignment of sensors
- Activate the remote control
- Configure CAN bus parameters
DIL Switch | Status | Function |
|---|---|---|
S5.1 |
| Reversing the motor rotation direction |
S5.2 | OFF | Analogue input for sensor 1 deactivated |
ON | Analogue input for sensor 1 activated | |
S5.3 | OFF | Analogue input for sensor 2 deactivated |
ON | Analogue input for sensor 2 activated | |
S5.4 |
| Invert the sensor signal for sensor 1 and sensor 2 |
S5.5 | OFF | Remote control inputs activated |
ON | Remote control inputs deactivated | |
S5.6 | OFF | Connector socket X101 is configured as internal BST CAN bus, i.e. it behaves in the same manner as connector sockets X100, X102, X103, X104 |
ON | Connector socket X101 is configured as external CAN bus (networked) |
DIL Switch | Baud Rate | Note | |
|---|---|---|---|
S5.7 | S5.8 | ||
OFF | OFF | 500 kBit | Applies only for connector socket X101 with galvanic separation. The connector sockets X100, X102, X103, X104 are always operated with 500 Kbit and without galvanic separation. |
ON | OFF | 125 kBit | |
OFF | ON | 250 kBit | |
ON | ON | 1 Mbit | |