Function Tables
Function table 0, factory setting | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Not used | |
Function table 1 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Selection of parameter sets 1 to 4 for the guiding setpoint (terminal assignment, see Selection of Parameter Set For The Guiding Setpoint) | |
12 | 23 | ||
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Not used | |
Function table 2 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | External limit switch 1 (stroke limitation) | |
12 | 23 | External limit switch 2 (stroke limitation) | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Not used | |
Function table 3 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | 1 = OK relay is used for status of the line monitoring | |
Outputs | 1 | 26 | Warning line position |
2 | 27 | Error line position | |
3 | 28 | Warning line width | |
4 | 29 | Error line width | |
Function table 4 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Accept the current web position analogue Sensor 2 as guiding setpoint for analogue Sensor 1 or vice-versa | |
7 | 18 | Inversion of the value accepted for the guiding setpoint | |
8 | 19 | When accepting the guiding setpoint, the input signal of the EFE 1 is included. DIL switch S4.3 must be OFF. | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Selection of parameter sets 1 to 4 for the guiding setpoint (terminal assignment, see Selection of Parameter Set For The Guiding Setpoint) | |
12 | 23 | ||
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Not used | |
Function table 5 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Accept current position of a web edge as guiding setpoint | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Line/contrast sensor CLS Pro 600: Controller interlock, | |
Function table 6 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Accept current position of a web edge as guiding setpoint | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Selection of parameter sets 1 to 4 for the guiding setpoint (terminal assignment, see Selection of Parameter Set For The Guiding Setpoint) | |
12 | 23 | ||
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Line/contrast sensor CLS Pro 600: | |
Function table 7 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Automatic | |
3 | 28 | Manual mode | |
4 | 29 | Centre positioning | |
Function table 8 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | Oscillation on/off | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Controller interlock (only for automatic mode) | |
Function table 9 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Width measurement warning | |
3 | 28 | Width measurement error | |
4 | 29 | Not used | |
Function table 10 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Moving the sensor slide of positioning unit 1 to the left | |
9 | 20 | Moving the sensor slide of positioning unit 1 to the right | |
10 | 21 | Moving the sensor slide of positioning unit 2 to the left | |
11 | 22 | Moving the sensor slide of positioning unit 2 to the right | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Not used | |
Function table 11 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Material in Sensor 1* | |
4 | 29 | Material in Sensor 2* | |
* Indicates that there is material within the sensor scanning area (even with full coverage of the sensor scanning area)
Function table 12 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Keyboard interlock | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | The selected sensor has detected a web edge.** | |
3 | 28 | Sensor 1 has detected a web edge.** | |
4 | 29 | Sensor 2 has detected a web edge.** | |
** With full coverage of the sensor scanning area no web edge will be detected.
Function table 13 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Keyboard interlock | |
5 | 14 | Web edge guiding Sensor 2 | |
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Web edge guiding Sensor 1 | |
10 | 21 | Controller interlock (only for automatic mode) | |
11 | 22 | Setup lock | |
12 | 23 | Not used | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Not used | |
Function table 14 |
|---|
Reserved for special applications |
Function table 15 | |||
|---|---|---|---|
Inputs / outputs | No. | Terminal | Function |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning |
2 | 11 | ||
3 | 12 | ||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | |
5 | 14 | ||
6 | 15 | Arrow key right, arrow key left | |
7 | 18 | ||
8 | 19 | Line / contrast / feature guiding Sensor 3 | |
9 | 20 | Combi sensor: Sensor A active | |
10 | 21 | Combi sensor: Sensor B active | |
11 | 22 | Combi sensor on sensor positioner: Sensor A active | |
12 | 23 | Combi sensor on sensor positioner: Sensor B active | |
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | |
3 | 28 | Brake function (actuator EMS 23B) | |
4 | 29 | Not used | |
Function table 16 |
| |||
|---|---|---|---|---|
Inputs / outputs | No. | Terminal | Function | |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning | |
2 | 11 | |||
3 | 12 | |||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | ||
5 | 14 | |||
6 | 15 | Arrow key right, arrow key left | ||
7 | 18 | |||
8 | 19 | Line / contrast / feature guiding Sensor 3 | ||
9 | 20 | Controller interlock web edge guiding Sensor 1 | ||
10 | 21 | Controller interlock web edge guiding Sensor 2 | ||
11 | 22 | Keyboard interlock | ||
12 | 23 | Not used | ||
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic | |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | ||
3 | 28 | Brake function (actuator EMS 23B) | ||
4 | 29 | Controller interlock (blocking) | ||
Function table 17 |
| |||
|---|---|---|---|---|
Inputs / outputs | No. | Terminal | Function | |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning | |
2 | 11 | |||
3 | 12 | |||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | ||
5 | 14 | |||
6 | 15 | Arrow key right, arrow key left | ||
7 | 18 | |||
8 | 19 | Line / contrast / feature guiding Sensor 3 | ||
9 | 20 | Keyboard interlock | ||
10 | 21 | Controller interlock (only for automatic mode) | ||
11 | 22 | External limit switch 1 (stroke limitation), | ||
12 | 23 | External limit switch 2 (stroke limitation), | ||
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic | |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | ||
3 | 28 | Brake function (actuator EMS 23B) | ||
4 | 29 | Not used | ||
Function table 18 |
| |||
|---|---|---|---|---|
Inputs / outputs | No. | Terminal | Function | |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning | |
2 | 11 | |||
3 | 12 | |||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | ||
5 | 14 | |||
6 | 15 | Arrow key right, arrow key left | ||
7 | 18 | |||
8 | 19 | Line / contrast / feature guiding Sensor 3 | ||
9 | 20 | Keyboard interlock | ||
10 | 21 | Controller interlock (only for automatic mode) | ||
11 | 22 | Take over the current ACTUAL position as the SETPOINT position for the selected guiding mode Requirement: | ||
12 | 23 | Reset the SETPOINT position for the selected guiding mode to "0“ | ||
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic | |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | ||
3 | 28 | Brake function (actuator EMS 23B) | ||
4 | 29 | Line/contrast sensor CLS Pro 600: Controller interlock, | ||
Function table 19 |
| |||
|---|---|---|---|---|
Inputs / outputs | No. | Terminal | Function | |
Inputs | 1 | 10 | Automatic, Manual mode, Centre positioning | |
2 | 11 | |||
3 | 12 | |||
4 | 13 | Web edge guiding Sensor 1, Web edge guiding Sensor 2, | ||
5 | 14 | |||
6 | 15 | Arrow key right, arrow key left | ||
7 | 18 | |||
8 | 19 | Line / contrast / feature guiding Sensor 3 | ||
9 | 20 | Keyboard interlock | ||
10 | 21 | Controller interlock (only for automatic mode) | ||
11 | 22 | Setup lock | ||
12 | 23 | Not used | ||
Outputs | 1 | 26 | Position of the guiding device corrected in operating mode automatic | |
2 | 27 | Software limit switch active/Motor overcurrent/Guiding device in end position | ||
3 | 28 | Brake function (actuator EMS 23B) | ||
4 | 29 | Dead zone operation: | ||