X60 - Actuator Connection EMS 17/18/21/22
The actuator is connected to the controller using an 8-pin micro-style connector M12 according to DIN IEC 61076.

For connecting the actuators EMS 17, EMS 21 and EMS 22, you require an optional adapter cable (order number 154 374), see also Accessories
Rotate the smartphone by 90 degrees to show the entire table.
Contact | Signal | Wire colour | Note |
|---|---|---|---|
1 | +24 V⎓ | white | Leads internally to terminal strip X7 |
2 | PWM (+) | brown | |
3 | PWM (0 V⎓) | green | |
4 | 0 V⎓ | yellow | |
5 | PWM (+) | grey | |
6 | PWM (0 V⎓) | pink | |
7 | Internal Pull UP | blue | |
8 | 0 – 10 V⎓ / 0 – 24 V⎓ | red |