Acceptance Modes

The function supports four acceptance modes. You activate the different acceptance modes in the public list of parameters of the controller (see Parameter List 0).

Acceptance mode 1: Automatic acceptance when changing into Automatic Mode

  • The acceptance mode is activated (Parameter w-setup man->auto = ON).
  • The controller is in operating mode Manual or Center Positioning.
  • The material web is located in the desired position.
  • Press the Automatic key.
  • The controller regulates according to the position of the web edge that was found when switching to the Automatic Mode.

Acceptance mode 2: Manual acceptance in Manual Mode

  • The acceptance mode is activated (Parameter w-setup by command = ON).
  • The controller is in operating mode Manual.
  • The material web is located in the desired position.
  • Press the ENTER key.
  • The controller accepts the current position of the web edge as the new guiding setpoint for the web guiding.

Acceptance mode 3: Automatic acceptance with remote control signal

  • The acceptance mode is activated (Parameter w-setup by input = ON).
  • Function table 5 (Table 5) or 6 (Table 6) for the allocation of the digital inputs and outputs is active. For selecting the function table see installation and commissioning manual , document number .
  • A respective remote control signal is present at terminal 22 of the controller.
  • The material web is located in the desired position.
  • Switch on the remote control signal.
  • The controller regulates according to the position of the web edge that was found when switching on the remote control signal.

Acceptance mode 4: Automatic acceptance with change of the guiding mode

  • The acceptance mode is activated (Parameter w-setup by edge change = ON).
  • The controller is in operating mode Automatic.
  • The material web is located in the desired position.
  • Press the key(s) for the desired guiding mode.

Key(s)

Guiding Mode

Guiding to the left web edge
(Sensor 1)

Guiding to the right web edge
(Sensor 2)

Web center-line guiding
(Sensor 1 and Sensor 2)

Line / contrast guiding
(Sensor 3)

The controller accepts the current position of the web edge as the new guiding setpoint for the web guiding.