The parameters in this parameter list are used to determine the following basic settings for the operation of the controller with CCD camera:

  • Definition of the bar and hole width of the calibration template used
  • Hole and bar width of the calibration template
  • Activation of the linearization function for the camera measuring range (guiding is carried out with linearized customer data)
Rotate the smartphone by 90 degrees to show the entire table.

Function

Parameter

Description

Parameter
value

Note

Factory
setting

Bar / hole width
of the calibration
template defined

width of bar µm

Width of the bar

0

65,000 µm

Standard calibration
template:
Bar width = 10 mm

10,000 µm
(Standard
calibration
template)

width of hole µm

Width of the hole

0

65,000 µm

Standard calibration
template:
Hole width = 10 mm

10,000 µm
(Standard
calibration
template)

Activate the
linearisation of
the camera range

Use calibr. CCD1

Linearization for
Sensor 1

0
(OFF)

Use of non-
linearized data

0
(OFF)

1
(ON)

Use of linearized
data*

 

Use calibr. CCD2

Linearization for
ensor 2

0
(OFF)

Use of non-
linearized data

0
(OFF)

1
(ON)

Use of linearized
data*

 

* Prerequisite: The CCD camera has been calibrated (see installation and commissioning manual , document number ).