Setting DIL Switch S4

Using DIL switch S4, carry out the following settings:

  • Reverse the guiding direction
  • Activate electronic remote precision adjustment EFE 1
  • Select the actuator to be used
  • Select the servo center transducer to be used

 

DIL Switch

Function

S4.1

Reverse the guiding direction for automatic mode
(Sensor 1, Sensor 2, Web center-line guiding)

S4.2

Reverse the guiding direction for the servo center transducer (see also Function of DIL switch S5.1)

S4.3 = ON

Electronic remote precision adjustment EFE 1 active
(adjustment of the guiding setpoint is not possible using the arrow keys)

 

Rotate the smartphone by 90 degrees to show the entire table.

DIL Switch

Actuator Used

S4.4

S4.5

S4.6

OFF

OFF

OFF

EMS 10, EMS 16, EMS 17, EMS 18

ON

OFF

OFF

EMS 5

OFF

ON

OFF

reserved

ON

ON

OFF

COMPACTGuide

OFF

OFF

ON

EMS 21, EMS 22, ECO EMS 22

ON

OFF

ON

reserved

OFF

ON

ON

reserved

ON

ON

ON

EMS 18/FG/Step, EMS 23, EMS DRV 400, PLG 320 (brushless)*

The actuator EMS 18 is automatically detected by the controller. The settings of the DIL switches S4.4 to S4.6 are disregarded in this case.

Rotate the smartphone by 90 degrees to show the entire table.

DIL Switch

Servo Center Transducer Used

S4.7

S4.8

OFF

OFF

Position feedback EMS 17 … 22**
(potentiometer),
position feedback EMS DRV 400

ON

OFF

OMG 8, CK 37

OFF

ON

No servo center transducer
(operating mode Center positioning cannot be selected)

ON

ON

OMG 4***

* in conjunction with Motordrive ECO

** not for actuator ECO EMS 22

*** not for actuator EMS 18/FG/Step