CCD Camera Calibration

This function is no longer available from firmware version 1.9.16 of the ekr commander control panel. In this case, the CCD camera calibration is performed on the CCD CAM 100 camera. For the procedure, please refer to the separate installation and operating manual CCD CAM 100, document number MD.465.
DANGER
Danger of death caused by the machine starting up!

Parts of your body could be crushed, cut, drawn in or hit.

  • Switch off the machine completely and secure it against it being switched back on.
  • Carry out the calibration of the CCD camera only when the production machine is stationary.

The calibration of the CCD camera is carried out using a special setting menu.

  • »The CCD camera is aligned precisely mechanically. The procedure for alignment is described in the operating manual of the CCD camera.
  1. Select the CCD camera that has to be calibrated (sensor 1 or sensor 2).
  • With a dual-camera system, both CCD cameras must be calibrated one-after another.
  1. In the Setup menu, activate the setting menu Camera calibration (see Calling up the Setup Menu).
  • The setting menu for the calibration of the CCD camera appears in the display.

Setting menu for the calibration of the CCD camera.

Number of contrast transitions detected

Number of visible contrast transitions

  1. Press the > arrow button.
  • The calibration procedure starts.
  • During the calibration, the symbol of an hour glass appears in the display for approx. 30 seconds.
  • Once the procedure has finished, the results of the calibration are displayed.
  • Both values displayed (detected and visible contrast transitions) should be identical (in ideal cases) or where possible, be positioned as close to one-another as possible.
  1. Press the > arrow button to conclude the calibration.
  • The setting menu is closed.
  • The edited parameter values are saved.
  • The setup menu is displayed.
If you want to carry out a compensation of the material thickness after the calibration of the CCD camera (recommended for thick materials), do not remove the calibration template.